{"title":"York Air Handlers","description":"","products":[{"product_id":"jhe18b5ab2ss1-york-1-5-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant","title":"York 1.5 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642962087,"sku":"JHE18B5AB2SS1","price":1730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9.jpg?v=1769924771"},{"product_id":"jhe24b5ac2ss1-york-2-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant","title":"York 2 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642994855,"sku":"JHE24B5AC2SS1","price":1770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_4cd5b87f-2f1a-4181-9b61-943721ef3c61.jpg?v=1769924806"},{"product_id":"jhe30b5ad2ss1-york-2-5-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant","title":"York 2.5 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643093159,"sku":"JHE30B5AD2SS1","price":1970.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_0bb10b4c-17cc-49c6-a173-f89d6c5bb20f.jpg?v=1769924839"},{"product_id":"jhe36b5cd2ss1-york-3-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-17-5-wide","title":"York 3 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (17.5\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643125927,"sku":"JHE36B5CD2SS1","price":1995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_71868bd8-26a5-43cc-b9a1-42974ea0ad5d.jpg?v=1769924874"},{"product_id":"jhe36c5ad2ss1-york-3-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-21-wide","title":"York 3 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643158695,"sku":"JHE36C5AD2SS1","price":2025.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_8948265a-2a3b-4c03-a753-18b0baf98204.jpg?v=1769924908"},{"product_id":"jhe42c5cf2ss1-york-3-5-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant","title":"York 3.5 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643191463,"sku":"JHE42C5CF2SS1","price":2115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_439c9913-c1e4-43e6-9650-0ea41d7c7570.jpg?v=1769924942"},{"product_id":"jhe48c5cg2ss1-york-4-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-21-wide","title":"York 4 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643289767,"sku":"JHE48C5CG2SS1","price":2240.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_ff8e177a-f102-43b7-a86d-2585e06f1f46.jpg?v=1769924976"},{"product_id":"jhc48c5cg2ss1-york-4-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-24-5-wide","title":"York 4 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (24.5\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642798247,"sku":"JHC48C5CG2SS1","price":2615.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_aedfc542-9eaf-4de7-90fb-a8c4f3885007.jpg?v=1769925011"},{"product_id":"jhe60c5ch2ss1-york-5-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-21-wide","title":"York 5 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643322535,"sku":"JHE60C5CH2SS1","price":2310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_4181f6c0-869d-4220-8e8c-ca6896e93582.jpg?v=1769925045"},{"product_id":"jhe60d5ch2ss1-york-5-ton-two-stage-air-handler-ecm-motor-for-r-454b-refrigerant-24-5-wide","title":"York 5 Ton Two-Stage Air Handler - ECM Motor for R-454B Refrigerant (24.5\" Wide)","description":"\u003cp\u003eThe York JHE Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNext generation high-efficiency blower Delivers increased airflow and reduced blower watts by 10%, using a standard ECM motor. \u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139643355303,"sku":"JHE60D5CH2SS1","price":2370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_3d368474-3f1e-44e2-a349-df97c58e45e4.jpg?v=1769925079"},{"product_id":"jhc18b5ab2ss1-york-1-5-ton-variable-speed-air-handler-for-r-454b-refrigerant","title":"York 1.5 Ton Variable Speed Air Handler for R-454B Refrigerant","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642503335,"sku":"JHC18B5AB2SS1","price":2010.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_b1bc044b-f85b-4191-a879-7cb112eed8dc.jpg?v=1769925113"},{"product_id":"jhc24b5ac2ss1-york-2-ton-variable-speed-air-handler-for-r-454b-refrigerant","title":"York 2 Ton Variable Speed Air Handler for R-454B Refrigerant","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642568871,"sku":"JHC24B5AC2SS1","price":2175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_755a4067-b9e0-4e9b-9b19-9e67e3c1ed23.jpg?v=1769925147"},{"product_id":"jhc36b5ad2ss1-york-3-ton-variable-speed-air-handler-for-r-454b-refrigerant-17-5-wide","title":"York 3 Ton Variable Speed Air Handler for R-454B Refrigerant (17.5\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642601639,"sku":"JHC36B5AD2SS1","price":2365.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_6439ab7b-7004-4f6a-8e08-3cbaca11af5a.jpg?v=1769925182"},{"product_id":"jhc36c5ad2ss1-york-3-ton-variable-speed-air-handler-for-r-454b-refrigerant-21-wide","title":"York 3 Ton Variable Speed Air Handler for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642667175,"sku":"JHC36C5AD2SS1","price":2395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_8e04f2d9-246c-455c-887a-1cf08b2b416c.jpg?v=1769925216"},{"product_id":"jhc42c5cf2ss1-york-3-5-ton-variable-speed-air-handler-for-r-454b-refrigerant-21-wide","title":"York 3.5 Ton Variable Speed Air Handler for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642732711,"sku":"JHC42C5CF2SS1","price":2460.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_813854b7-58ba-4e24-b678-2138de544130.jpg?v=1769925250"},{"product_id":"jhc42d5cf2ss1-york-3-5-ton-variable-speed-air-handler-for-r-454b-refrigerant-24-5-wide","title":"York 3.5 Ton Variable Speed Air Handler for R-454B Refrigerant (24.5\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642765479,"sku":"JHC42D5CF2SS1","price":2470.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_a7677ae4-1683-4f65-83f0-8f5ffe8fe2eb.jpg?v=1769925284"},{"product_id":"jhc48d5cg2ss1-york-4-ton-variable-speed-air-handler-for-r-454b-refrigerant-24-5-wide","title":"York 4 Ton Variable Speed Air Handler for R-454B Refrigerant (24.5\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642896551,"sku":"JHC48D5CG2SS1","price":2620.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_f5015f6d-3c54-4f06-a5c9-bfae866406da.jpg?v=1769925318"},{"product_id":"jhc60c5ch2ss1-york-5-ton-variable-speed-air-handler-for-r-454b-refrigerant-21-wide","title":"York 5 Ton Variable Speed Air Handler for R-454B Refrigerant (21\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":48139642929319,"sku":"JHC60C5CH2SS1","price":2685.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_135eb2d1-9783-4f85-b72b-2470d777188e.jpg?v=1769925352"},{"product_id":"jhc60d5cj2ss1-york-5-ton-variable-speed-air-handler-for-r-454b-refrigerant-24-5-wide","title":"York 5 Ton Variable Speed Air Handler for R-454B Refrigerant (24.5\" Wide)","description":"\u003cp\u003eThe York JHC Air Handler provides the flexibility for installation in upflow, downflow, horizontal right, or horizontal left applications. These units may be located in a closet, utility room, attic, crawl space, or basement. These versatile models may be used for cooling or heat pump operation with or without electric heat. Top or side power and control wiring, color-coded leads for control wiring, and electric heaters all combine to make the installation easy and minimize installation cost. Electric heat kits are available as field-installed accessories.  An R-454B refrigerant detection system (RDS) is factory installed.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaxAlloyTM coil Long-life aluminum coils built to deliver lasting performance, efficiency, and reliability\u003c\/li\u003e\n\u003cli\u003eNext generation even-flow distributor: Designed for balanced refrigerant flow and even coil circuit performance\u003c\/li\u003e\n\u003cli\u003eNext generation high-efficiency blower: Delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor\u003c\/li\u003e\n\u003cli\u003eVariable speed operation Provides flexibility in application as well as upgraded system efficiency\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation Provides flexibility in application with single and two-stage outdoor equipment. \u003c\/li\u003e\n\u003cli\u003eNext generation insulation and gasket design Reduces thermal transmission paths and reduces sweating. \u003c\/li\u003e\n\u003cli\u003eNine speed standard ECM blower motor Provides increased system compatibility. \u003c\/li\u003e\n\u003cli\u003eDesigned for easy installation and service\u003c\/li\u003e\n\u003cli\u003eA casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs and integrated duct flanges shorten install time. \u003c\/li\u003e\n\u003cli\u003eModular blower control board: The control board can be controlled with a standard (conventional) thermostat or with a HX communicating control. \u003c\/li\u003e\n\u003cli\u003eCabinet air leakage: Less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193. \u003c\/li\u003e\n\u003cli\u003eLong lasting quality: Structural components made of post powder painted steel or galvanized steel to prevent corrosion. \u003c\/li\u003e\n\u003cli\u003eThermostat drain pan: Positive slope for drainage to reduce cause for potential mold or contaminant\u003c\/li\u003e\n\u003cli\u003eA2L refrigerant ready: An R-454B refrigerant detection system (RDS) is factory installed. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":47776925810855,"sku":"JHC60D5CJ2SS1","price":2695.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/york-air-handler_9_b0868985-c283-4609-9161-b9aaff1c5b6d.jpg?v=1769925386"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/collections\/Air_Handlers_e9a00983-d55f-428e-8df6-8990c7551aeb.png?v=1774732791","url":"https:\/\/theacoutlet.com\/collections\/air-handlers-york.oembed","provider":"The AC Outlet","version":"1.0","type":"link"}