{"product_id":"288bnv060000a-fv4anf006l00-5-ton-15-seer-bryant-heat-pump-system","title":"5 Ton 15 Seer Bryant Heat Pump System","description":"\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eThe Bryant 288BNV Heat Pump\u003c\/span\u003e\u003c\/b\u003e offers high-efficiency variable speed performance in a remarkably small cabinet and provides up to 11 HSPF heating efficiency and up to 18 SEER cooling efficiency. The variable speed inverter capacity control delivers up to 5 stages of operation for exceptional load matching, dehumidification and zoning performance. This product has been designed and manufactured to provide flexible system matching and work with a wide variety of indoor units and controls.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eStandard Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEnergy Efficiency\u003c\/li\u003e\r\n\u003cli\u003eUp to 18 SEER \/12.5 EER \/ 11 HSPF\u003c\/li\u003e\r\n\u003cli\u003eMicrotube Technology refrigeration system\u003c\/li\u003e\r\n\u003cli\u003eSound level as low as 55 dBA in low speed, Silencer System II\u003c\/li\u003e\r\n\u003cli\u003eSoft start and smooth ramp to operating speeds\u003c\/li\u003e\r\n\u003cli\u003eVariable speed compressor operates at 5 stages with capacity range from as wide as 25-100%\u003c\/li\u003e\r\n\u003cli\u003eAir cooled Inverter variable speed drive\u003c\/li\u003e\r\n\u003cli\u003eSystem requires Evolution Connex Control with version 11 software or newer for 5-stage operation\u003c\/li\u003e\r\n\u003cli\u003eRatings provided with 2-stage thermostats and suitable\u003c\/li\u003e\r\n\u003cli\u003enon-communicating indoor products for 2-stage operation\u003c\/li\u003e\r\n\u003cli\u003ePuron refrigerant environmentally sound, won't deplete the ozone layer and low lifetime service cost\u003c\/li\u003e\r\n\u003cli\u003eInternal crankcase heater standard\u003c\/li\u003e\r\n\u003cli\u003e2 control wires to outdoor unit in complete Evolution system and Connex Control\u003c\/li\u003e\r\n\u003cli\u003eSmaller and lighter than 2-stage units\u003c\/li\u003e\r\n\u003cli\u003eMinimum and Maximum adjustments with Evolution Connex Control\u003c\/li\u003e\r\n\u003cli\u003eHybrid Heat dual fuel capable\u003c\/li\u003e\r\n\u003cli\u003eCompatible with non-communicating thermostats\u003c\/li\u003e\r\n\u003cli\u003eDuraGuard protection package\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cb\u003e\u003cspan style=\"font-size: medium;\"\u003eCabinet Features:\u003c\/span\u003e\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eSolid, Durable sheet metal construction\u003c\/li\u003e\r\n\u003cli\u003eSteel louver coil guard\u003c\/li\u003e\r\n\u003cli\u003eFront-seating service valves\u003c\/li\u003e\r\n\u003cli\u003eInverter control drives compressor and fan motor\u003c\/li\u003e\r\n\u003cli\u003eNo control module attached to fan motor\u003c\/li\u003e\r\n\u003cli\u003eEvolution intelligence monitors critical system parameters\u003c\/li\u003e\r\n\u003cli\u003ePressure equalizer valve for easy compressor starting\u003c\/li\u003e\r\n\u003cli\u003eHigh pressure switch\u003c\/li\u003e\r\n\u003cli\u003eSuction pressure transducer\u003c\/li\u003e\r\n\u003cli\u003eElectronic expansion valve EXV for heating, TXV for cooling\u003c\/li\u003e\r\n\u003cli\u003eCompressor discharge temperature sensor\u003c\/li\u003e\r\n\u003cli\u003eSuction temperature sensor\u003c\/li\u003e\r\n\u003cli\u003eFilter drier field installed\u003c\/li\u003e\r\n\u003cli\u003eBaked-on, complete outer coverage, powder paint\u003c\/li\u003e\r\n\u003cli\u003eLine sets up to 100 ft, 30.5 m equivalent length\u003c\/li\u003e\r\n\u003cli\u003eNo long-line accessories required\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e\r\n\u003cp\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eThe Bryant FV4C Air Handler\u003c\/strong\u003e\u003c\/span\u003e combines the proven technology of Bryant fan coils with environmentally sound Puron refrigerant. The FV4C achieves an operational advantage when the ECM (Electronically Commutated Motor) is combined with a Bryant Preferred heat pump with Puron refrigerant.\u003cbr\u003eWith attention to quiet, efficient, and comfortable operation, Bryant has developed a new benchmark for superior indoor comfort and control. ArmorCoat provides a tin plating of the indoor coils copper hairpins. This creates a barrier between the corrosion-causing elements and the coil.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003eBryant's heat pump and air conditioning systems now feature Puron refrigerant (R-410A), the chlorine-free refrigerant that is the future for the residential heating and cooling industry. The FV4C using Puron refrigerant maximizes performance for environmentally sound systems. In addition to environmental safety, these systems are 30 to 40 more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental safety.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003eThe FV4C provides these benefits due to Bryant's command of ECM technology. These motors are extremely efficient at all speeds, and enable the FV4C to operate at the correct speed to deliver airflow precisely, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also makes installation quality easier to achieve for today's demanding homeowner.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003eBryant's command of ECM technology may be most evident in the comfort advantages that ECM can deliver. Operation set up steps on the Easy Select Board provide the installing technician with alternatives to maximize comfort and efficiency. For true indoor comfort, the homeowner can achieve command of both temperature and humidity in cooling and heating modes.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003eAnother feature which sets the FV4C apart is the factory-installed TXV, which enhances efficiency and provides compressor protecting operation at all recommended conditions. Grooved copper tubing, louvered aluminum fins, and the large face areas of the FV4C refrigerant coils also provide superior efficiency, for high SEER and HSPF performance. Bryant leads the way in condensate control, a hallmark of these multipoise fan coils. All of these featured components are protected within a rugged, prepainted metal cabinet lined with super thick, high-density insulation. For neat, high-quality installations the unit exterior features sweat refrigerant connections for simple leak free performance, and multiple electrical entry for both high and low voltage service.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003eFor superior technology and unmatched comfort, the environmentally sound and efficient FV4C can't be beat.\u003c\/p\u003e\r\n\u003cp\u003e\u003cbr\u003e\u003cspan style=\"font-size: medium;\"\u003e\u003cstrong\u003eStandard Features:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eEnvironmentally Sound Refrigerant Technology inches Puron, chlorine-free non-ozone depleting refrigerant. Thermostatic Expansion Valve (TXV) designed to maximize performance with Puron refrigerant.\u003c\/li\u003e\r\n\u003cli\u003eEnergy Efficient Operation inches Electronically Commutating Motor (ECM) operates efficiently at all speeds. Maximizes efficiency of heating and cooling systems. Ultra low power consumption during fan only operation.\u003c\/li\u003e\r\n\u003cli\u003eIndoor Weather Control inches Warm, comfortable heating air temperatures. Unmatched humidity control, especially with Bryants Thermidistatž˘ Control.\u003c\/li\u003e\r\n\u003cli\u003eAirflow and Sound Technology inches Diffuser air discharge section for high airflow efficiency and quiet, smooth operation. High duct static capability. Unique cabinet design that meets new stringent regulations for air leakage. Meets requirements of a 2 cabinet leakage rate when tested at 1.0 inches of static pressure.\u003c\/li\u003e\r\n\u003cli\u003eCondensate Control and Disposal Technology inches Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage. Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance. Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions. Tested for condensate disposal at conditions much more severe than those required by AHRI. Primary and secondary drain connections to comply with HUD. All pans constructed of an injection molded glass-filled polycarbonate engineered resin material, with brass drain connections. High density, super thick cabinetry insulation with vapor barrier. Pre-painted galvanized sheet metal cabinet.\u003c\/li\u003e\r\n\u003cli\u003eHeat Transfer Technology inches Grooved copper tubing. Lanced sine wave aluminum fins. Discreet refined counter-flow refrigerant circuitry. Bi-flow hard shut-off TXV metering device. ArmorCoatž˘ coil protection available.\u003c\/li\u003e\r\n\u003cli\u003eQuality Assisting, Ease of Installation and Service Features inches All units multipoise. Provision made for suspending from roof or ceiling joints. Modular cabinet on 003 thru 006 units. Sweat connections for leak free service. Multiple electrical entry for application flexibility (high and low voltage). Low voltage terminal strip, to safely hold connections within the cabinet. Inspection plate on A-coil models for quick coil cleanliness inspection. Cabinet construction features innovations designed to prevent cabinet sweating.\u003c\/li\u003e\r\n\u003cli\u003eControls and Electrical Features inches Easy Select Board to maximize comfort, efficiency, and safe heater airflow operation. Easy plug connection provided for quick installation of accessory heater packages. 40VA 208\/230v transformer. Replaceable 5-amp blade-type auto fuse protects against transformer secondary short.\u003c\/li\u003e\r\n\u003cli\u003eFilter Features inches Factory supplied filter. Cleanable polyester filter media. Filter springs inches out for easy access - no tools required. Newly improved filter rack area - filter door insulation added for an improved air seal.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e \u003c\/p\u003e","brand":"Bryant","offers":[{"title":"Default Title","offer_id":48136918859943,"sku":"288BNV060000A - FV4ANF006L00","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0727\/0416\/4007\/files\/bryant-114-116bn-213cn-215bn-fb-fe-fv-fx-system_2_520dca3a-53f5-4ae5-ab65-dc4cdbb82f83.png?v=1769242188","url":"https:\/\/theacoutlet.com\/products\/288bnv060000a-fv4anf006l00-5-ton-15-seer-bryant-heat-pump-system","provider":"The AC Outlet","version":"1.0","type":"link"}